S19 XP+ Hyd
| Performance Curves
1. Hashrate vs. Inlet Coolant Temperature
2. Power Efficiency vs. Inlet Coolant Temperature
(1-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.
| Specifications
| Product Glance | Value |
| Model | S19 XP+ Hyd. |
| Crypto algorithm/coins | SHA256 | BTC/BCH/BSV |
| Typical hashrate, TH/s(2-1) | 279 |
| Power on wall @35°C(2-2), Watt(2-1) | 5,301 |
| Power efficiency on wall @35°C(2-2), J/TH(2-1) | 19 |
| Detailed Characteristics | Value |
| Power Supply | |
| Phase | 3 |
| Input voltage, Volt(2-1) | 380~415 |
| Input Frequency Range, Hz | 50~60 |
| Input max current, Amp | 12 |
| Hardware Configuration | |
| Networking connection mode | RJ45 Ethernet 10/100M |
| Server Size (Length*Width*Height, w/o package), mm | 339*173*207 |
| Server Size (Length*Width*Height, with package), mm | 570*316*430 |
| Net weight, kg(3-2) | 12.3 |
| Gross weight, kg | 13.6 |
| Environment Requirements | |
|
Inlet coolant temperature,°C
|
20~50 |
|
Coolant flow, L/min
|
8.0~10.0 |
|
Coolant pressure, bar
|
≤3.5 |
|
Working coolant(3-2)
|
Antifreeze/ Pure water/Deionized water
|
|
Coolant pH value
|
Antifreeze: 7.0~9.0
Pure water: 6.5~7.5
Deionized water:8.5~9.5
|
|
Diameter of coolant pipe connector, mm
|
OD10 |
| Storage temperature,°C | -20~70 |
| Operation humidity(non-condensing) , RH | 10~90% |
Notes:
(2-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.
(2-2) Inlet coolant temperature.
(3-1) Caution: Wrong input voltage may cause server damaged.
(3-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Hydro Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!