T19 Pro Hyd
| Function | BTC/BCH/BSV SHA256 Hydro-cooling Miner |
| Specifications | 235T 5170W 22J/T |
| Specifications
| Product Glance | |
| Model | T19 Pro Hyd. |
| Algorithm | Cryptocurrency | SHA256 | BTC/BCH/BSV |
| Typical Hashrate, TH/s(1-1) | 246 |
| Power on wall @35°C(1-2), Watt(1-1) | 5412 |
| Power efficiency on wall @35°C(1-2), J/TH(1-1) | 22 |
| Detailed Characteristics | |
| Power supply | |
| Power supply AC input voltage, Volt(2-1) | 380~415 |
| Power supply AC input frequency range, Hz | 50~60 |
| Power supply AC input current, Amp(2-2) | 12 |
| Hardware configuration | |
| Network connection mode | RJ45 Ethernet 10/100M |
| Miner size (length*width*height, w/o package),mm | 410*170*209 |
| Miner size (length*width*height, with package),mm | 570*316*430 |
| Net weight, kg | 12.8 |
| Gross weight, kg | 14.1 |
| Environment requirements | |
| Inlet water temperature, °C(2-3) | 20~50 |
| Water flow, L/min | 8.0~10.0 |
| Water pressure, bar | ≤3.5 |
| Working fluid(2-4) | Antifreeze/ Deionized water/ Pure water |
| Liquid PH | 8.5~9.5 |
| Diameter of water pipe connector, mm | DN10 |
| Storage temperature, °C | -20~70 |
| Operation humidity(non-condensing), RH | 10%~90% |
NOTE:
(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%.
(1-2) Inlet water temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) Three-phase AC input, 12A max.
(2-3) If the inlet water temperature is lower than 20 °C, the miner cannot be started. For the external dry cooler (EC2-DT),
• if the outlet water temperature is 35°C, the maximum ambient temperature is 30°C;
• if the outlet water temperature is 45°C, the maximum ambient temperature is 40°C;
• if the outlet water temperature is 50°C, the maximum ambient temperature is 45°C.
(2-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.